Section : __________________________
QUIZ #6
Reference Data for Engineers 5-17 to end
HP 8116A 50 MHz Function Generator
HP 5314A Universal Counter
Fluke PM6304 RCL Meter
Directions: This quiz consists of 2 pages
and 20 questions. All the answers for questions are worth 1 point each.
Be sure to place your name and section at the top of this page.
The following statements are either True or False :
1. Moisture has great effect on the dielectric properties of plastic films, and capacitors made from them require more protection than paper/ mica types.
2. Printed circuit construction is ideal for assembly of circuits that employ miniature solid state components.
3. In a HP8116A a DC output voltage is generated when all waveform selection keys are deactivated .
4. In TRIG mode of HP8116A, each active input edge triggers more than one output cycle.
5. The maximum output frequency in a burst mode in HP8116A is 40MHz.
6. The available pulse width ranges are not limited by the current output frequency in a HP5314A Universal counter.
7. The HP5314A Universal counter is a Safety Class 1 instrument designed according to International safety standards.
8. In HP5314A, all period measurements are made through the A channel input.
9. HP 5314A does not have a built-in self check function.
10. Resistor, inductor and capacitors are ideal electrical components and have no secondary effects that limit their performance.
Complete the following:
inter-electrode space is termed the ________________________ and the ratio of this to the test voltage is
the _________________________.
12. There are _____________________ broad classes of capacitors. Namely, ______________________,
_____________________________, _____________________________
.
13. A printed circuit is a _________________ circuit pattern on one or both side of a
____________________ substrate.
14. The frequency range of HP8116A
is ____________________________________________.
15. The Standard Parameter Set exists for two reasons. Namely,
_________________________________, _______________________________________.
16. Output level in HP8116A can be set in terms of ________________ or in terms of
_____________________.
17. The HP5314A has frequency range
of _____________________________________ .
18. The component measurement in
PM6304 is based on the ______________________ technique.
19. PM6304 has frequency range
from __________________________________ .
20. Self – resonant frequency in
a RLC circuit is f 0 = ________________________ .